summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorP. J. McDermott <pj@pehjota.net>2017-08-21 18:28:45 (EDT)
committer P. J. McDermott <pj@pehjota.net>2017-08-21 18:28:45 (EDT)
commit6a8f5b4dac5b6ce0e36dd68d68ccf95516a542e6 (patch)
tree3e773549d8b4b22f77f80cfa198556687d574088
parentf7cdaecce80eb6ec0b16a8ed0ad2bc8b7aef319b (diff)
downloadprintrun-6a8f5b4dac5b6ce0e36dd68d68ccf95516a542e6.zip
printrun-6a8f5b4dac5b6ce0e36dd68d68ccf95516a542e6.tar.gz
printrun-6a8f5b4dac5b6ce0e36dd68d68ccf95516a542e6.tar.bz2
.pronsolerc: Drop macros
These don't work in Pronterface.
-rw-r--r--.pronsolerc62
1 files changed, 0 insertions, 62 deletions
diff --git a/.pronsolerc b/.pronsolerc
index 88a5207..6046a66 100644
--- a/.pronsolerc
+++ b/.pronsolerc
@@ -19,65 +19,3 @@ set last_temperature 240.0
set last_bed_temperature 110.0
set last_sash_position 333
set last_extrusion 10
-macro wipe_hips
- ; Set units, positioning modes, and extruder origin
- G21 ; Set units to millimeters
- G90 ; Set absolute positioning mode
- M82 ; Set E absolute mode (override G91)
- G92 E0 ; Set extruder position to 0 (origin)
- ; Begin heating hotend to HIPS retraction temperature
- M107 ; Turn off the print cooling fan
- M104 S150 ; Set hotend temperature without waiting
- M140 S110 ; Set bed temperature without waiting
- ; While waiting for the hotend to heat, auto-home the axes
- G28 ; Auto-home all axes
- M109 ; Wait for hotend temperature
- ; Retract filament before wiping
- G1 Z150 E-30 F75 ; Slowly lower Z and retract filament
- ; Begin heating hotend to HIPS wiping temperature
- M104 S170 ; Set hotend temperature without waiting
- ; While waiting for the hotend to heat, position the nozzle over the wiping pad
- G1 X45 Y174 Z10 F11520 ; Move nozzle to just over wiping pad
- M109 ; Wait for hotend temperature
- ; Wipe the nozzle
- G1 Z-0.5 F4000 ; Plunge nozzle into wiping pad
- G1 X55 Y172 F4000 ; Wipe
- G1 X45 Y174 Z0 F4000 ; Wipe
- G1 X55 Y172 F4000 ; Wipe
- G1 X45 Y174 F4000 ; Wipe
- G1 X55 Y172 F4000 ; Wipe
- G1 X45 Y174 F4000 ; Wipe
- G1 X55 Y172 F4000 ; Wipe
- G1 X60 Y174 F4000 ; Wipe
- G1 X80 Y172 F4000 ; Wipe
- G1 X60 Y174 F4000 ; Wipe
- G1 X80 Y172 F4000 ; Wipe
- G1 X60 Y174 F4000 ; Wipe
- G1 X90 Y172 F4000 ; Wipe
- G1 X80 Y174 F4000 ; Wipe
- G1 X100 Y172 F4000 ; Wipe
- G1 X80 Y174 F4000 ; Wipe
- G1 X100 Y172 F4000 ; Wipe
- G1 X80 Y174 F4000 ; Wipe
- G1 X100 Y172 F4000 ; Wipe
- G1 X110 Y174 F4000 ; Wipe
- G1 X100 Y172 F4000 ; Wipe
- G1 X110 Y174 F4000 ; Wipe
- G1 X100 Y172 F4000 ; Wipe
- G1 X110 Y174 F4000 ; Wipe
- G1 X115 Y172 Z-0.5 F1000 ; Wipe slower, bury nozzle in cleanish area
- G1 Z10 ; Lift out of wiping pad
- ; Begin heating hotend to HIPS probing temperature
- M104 S170 ; Set hotend temperature without waiting
- ; While waiting for the hotend to heat, auto-home X and Y
- G28 X0 Y0 ; Auto-home X and Y
- M109 ; Wait for hotend temperature
-macro probe
- ; Probe the bed and enable bed leveling compensation
- G1 Z10 F5000 ; Lift off the bed-leveling washer
- G28 X0 Y0 ; Auto-home X and Y
- M204 S300 ; Set acceleration for probing moves
- G29 ; Probe the bed
- M204 S2000 ; Set acceleration back to normal
- G1 Z10 F5000 ; Lift off the bed-leveling washer
- G1 X40 Y190 F5000 ; Move nozzle away and bed forward