From 6a8f5b4dac5b6ce0e36dd68d68ccf95516a542e6 Mon Sep 17 00:00:00 2001 From: P. J. McDermott Date: Mon, 21 Aug 2017 18:28:45 -0400 Subject: .pronsolerc: Drop macros These don't work in Pronterface. --- diff --git a/.pronsolerc b/.pronsolerc index 88a5207..6046a66 100644 --- a/.pronsolerc +++ b/.pronsolerc @@ -19,65 +19,3 @@ set last_temperature 240.0 set last_bed_temperature 110.0 set last_sash_position 333 set last_extrusion 10 -macro wipe_hips - ; Set units, positioning modes, and extruder origin - G21 ; Set units to millimeters - G90 ; Set absolute positioning mode - M82 ; Set E absolute mode (override G91) - G92 E0 ; Set extruder position to 0 (origin) - ; Begin heating hotend to HIPS retraction temperature - M107 ; Turn off the print cooling fan - M104 S150 ; Set hotend temperature without waiting - M140 S110 ; Set bed temperature without waiting - ; While waiting for the hotend to heat, auto-home the axes - G28 ; Auto-home all axes - M109 ; Wait for hotend temperature - ; Retract filament before wiping - G1 Z150 E-30 F75 ; Slowly lower Z and retract filament - ; Begin heating hotend to HIPS wiping temperature - M104 S170 ; Set hotend temperature without waiting - ; While waiting for the hotend to heat, position the nozzle over the wiping pad - G1 X45 Y174 Z10 F11520 ; Move nozzle to just over wiping pad - M109 ; Wait for hotend temperature - ; Wipe the nozzle - G1 Z-0.5 F4000 ; Plunge nozzle into wiping pad - G1 X55 Y172 F4000 ; Wipe - G1 X45 Y174 Z0 F4000 ; Wipe - G1 X55 Y172 F4000 ; Wipe - G1 X45 Y174 F4000 ; Wipe - G1 X55 Y172 F4000 ; Wipe - G1 X45 Y174 F4000 ; Wipe - G1 X55 Y172 F4000 ; Wipe - G1 X60 Y174 F4000 ; Wipe - G1 X80 Y172 F4000 ; Wipe - G1 X60 Y174 F4000 ; Wipe - G1 X80 Y172 F4000 ; Wipe - G1 X60 Y174 F4000 ; Wipe - G1 X90 Y172 F4000 ; Wipe - G1 X80 Y174 F4000 ; Wipe - G1 X100 Y172 F4000 ; Wipe - G1 X80 Y174 F4000 ; Wipe - G1 X100 Y172 F4000 ; Wipe - G1 X80 Y174 F4000 ; Wipe - G1 X100 Y172 F4000 ; Wipe - G1 X110 Y174 F4000 ; Wipe - G1 X100 Y172 F4000 ; Wipe - G1 X110 Y174 F4000 ; Wipe - G1 X100 Y172 F4000 ; Wipe - G1 X110 Y174 F4000 ; Wipe - G1 X115 Y172 Z-0.5 F1000 ; Wipe slower, bury nozzle in cleanish area - G1 Z10 ; Lift out of wiping pad - ; Begin heating hotend to HIPS probing temperature - M104 S170 ; Set hotend temperature without waiting - ; While waiting for the hotend to heat, auto-home X and Y - G28 X0 Y0 ; Auto-home X and Y - M109 ; Wait for hotend temperature -macro probe - ; Probe the bed and enable bed leveling compensation - G1 Z10 F5000 ; Lift off the bed-leveling washer - G28 X0 Y0 ; Auto-home X and Y - M204 S300 ; Set acceleration for probing moves - G29 ; Probe the bed - M204 S2000 ; Set acceleration back to normal - G1 Z10 F5000 ; Lift off the bed-leveling washer - G1 X40 Y190 F5000 ; Move nozzle away and bed forward -- cgit v0.9.1